{"id":19351,"date":"2025-10-21T14:44:26","date_gmt":"2025-10-21T14:44:26","guid":{"rendered":"https:\/\/zemgroup.com\/en\/?p=19351"},"modified":"2025-10-21T14:47:04","modified_gmt":"2025-10-21T14:47:04","slug":"regulations-of-the-engineering-organization-for-kitchen-construction","status":"publish","type":"post","link":"https:\/\/zemgroup.com\/en\/regulations-of-the-engineering-organization-for-kitchen-construction\/","title":{"rendered":"Regulations of the Engineering Organization for Kitchen Construction"},"content":{"rendered":"\t\t<div data-elementor-type=\"wp-post\" data-elementor-id=\"19351\" class=\"elementor elementor-19351\" data-elementor-post-type=\"post\">\n\t\t\t\t<div class=\"elementor-element elementor-element-9c973cd e-flex e-con-boxed e-con e-parent\" data-id=\"9c973cd\" data-element_type=\"container\">\n\t\t\t\t\t<div class=\"e-con-inner\">\n\t\t\t\t<div class=\"elementor-element elementor-element-f1cba68 color-scheme-inherit text-left elementor-widget elementor-widget-text-editor\" data-id=\"f1cba68\" data-element_type=\"widget\" data-widget_type=\"text-editor.default\">\n\t\t\t\t<div class=\"elementor-widget-container\">\n\t\t\t\t\t\t\t\t\t<p data-start=\"212\" data-end=\"707\">The kitchen is one of the most important spaces in any residential or commercial building, as its functionality and safety directly impact the comfort and health of occupants. This space is not only used for cooking and storing food but, with proper design and layout, can significantly enhance the user experience. The following provides a comprehensive review of architectural standards, electrical systems and outlets, civil engineering design, gas safety, and practical kitchen principles.<\/p>\n<p data-start=\"709\" data-end=\"856\">A kitchen is an area intended for food preparation and storage. From an architectural perspective, there are three main types of kitchen layouts:<\/p>\n<ul data-start=\"857\" data-end=\"926\">\n<li data-start=\"857\" data-end=\"884\">\n<p data-start=\"859\" data-end=\"884\"><strong data-start=\"859\" data-end=\"882\">Independent Kitchen<\/strong><\/p>\n<\/li>\n<li data-start=\"885\" data-end=\"905\">\n<p data-start=\"887\" data-end=\"905\"><strong data-start=\"887\" data-end=\"903\">Open Kitchen<\/strong><\/p>\n<\/li>\n<li data-start=\"906\" data-end=\"926\">\n<p data-start=\"908\" data-end=\"926\"><strong data-start=\"908\" data-end=\"924\">Wall Kitchen<\/strong><\/p>\n<\/li>\n<\/ul>\n<p data-start=\"928\" data-end=\"1036\">From a usage standpoint, kitchens can be categorized as <strong data-start=\"984\" data-end=\"1033\">residential, commercial\/public, or industrial<\/strong>.<\/p>\n<p data-start=\"928\" data-end=\"1036\"><img fetchpriority=\"high\" decoding=\"async\" class=\"aligncenter wp-image-19354 size-large\" src=\"http:\/\/zemgroup.com\/en\/wp-content\/uploads\/2025\/10\/\u067e\u0645-1250x800.jpg\" alt=\"\" width=\"1250\" height=\"800\" srcset=\"https:\/\/zemgroup.com\/en\/wp-content\/uploads\/2025\/10\/\u067e\u0645-1250x800.jpg 1250w, https:\/\/zemgroup.com\/en\/wp-content\/uploads\/2025\/10\/\u067e\u0645-400x256.jpg 400w, https:\/\/zemgroup.com\/en\/wp-content\/uploads\/2025\/10\/\u067e\u0645-768x492.jpg 768w, https:\/\/zemgroup.com\/en\/wp-content\/uploads\/2025\/10\/\u067e\u0645-1536x983.jpg 1536w, https:\/\/zemgroup.com\/en\/wp-content\/uploads\/2025\/10\/\u067e\u0645-860x550.jpg 860w, https:\/\/zemgroup.com\/en\/wp-content\/uploads\/2025\/10\/\u067e\u0645-430x275.jpg 430w, https:\/\/zemgroup.com\/en\/wp-content\/uploads\/2025\/10\/\u067e\u0645-700x448.jpg 700w, https:\/\/zemgroup.com\/en\/wp-content\/uploads\/2025\/10\/\u067e\u0645-150x96.jpg 150w, https:\/\/zemgroup.com\/en\/wp-content\/uploads\/2025\/10\/\u067e\u0645.jpg 1600w\" sizes=\"(max-width: 1250px) 100vw, 1250px\" \/><\/p>\n<hr data-start=\"1038\" data-end=\"1041\" \/>\n<h3 data-start=\"1043\" data-end=\"1079\">Electrical Systems and Outlets<\/h3>\n<p data-start=\"1081\" data-end=\"1176\">According to engineering regulations for kitchen wiring, the key requirements are as follows:<\/p>\n<p data-start=\"1178\" data-end=\"1191\"><strong data-start=\"1178\" data-end=\"1189\">Zoning:<\/strong><\/p>\n<ul data-start=\"1192\" data-end=\"1404\">\n<li data-start=\"1192\" data-end=\"1269\">\n<p data-start=\"1194\" data-end=\"1269\"><strong data-start=\"1194\" data-end=\"1205\">Zone 1:<\/strong> The interior of the kitchen up to 2.25 meters from the floor.<\/p>\n<\/li>\n<li data-start=\"1270\" data-end=\"1341\">\n<p data-start=\"1272\" data-end=\"1341\"><strong data-start=\"1272\" data-end=\"1283\">Zone 2:<\/strong> Kitchen space from 0.6 meters to 2.25 meters in height.<\/p>\n<\/li>\n<li data-start=\"1342\" data-end=\"1404\">\n<p data-start=\"1344\" data-end=\"1404\"><strong data-start=\"1344\" data-end=\"1376\">Areas outside Zones 1 and 2:<\/strong> All other kitchen spaces.<\/p>\n<\/li>\n<\/ul>\n<p data-start=\"1406\" data-end=\"1457\"><strong data-start=\"1406\" data-end=\"1455\">Electrical Equipment and Outlet Requirements:<\/strong><\/p>\n<ul data-start=\"1458\" data-end=\"2207\">\n<li data-start=\"1458\" data-end=\"1578\">\n<p data-start=\"1460\" data-end=\"1578\">In Zones 1 and 2, all electrical devices, including outlets and switches, must be waterproof and moisture-resistant.<\/p>\n<\/li>\n<li data-start=\"1579\" data-end=\"1663\">\n<p data-start=\"1581\" data-end=\"1663\">Outlets in Zones 1 and 2 must be protected with residual current devices (RCDs).<\/p>\n<\/li>\n<li data-start=\"1664\" data-end=\"1760\">\n<p data-start=\"1666\" data-end=\"1760\">In <strong data-start=\"1669\" data-end=\"1679\">Zone 1<\/strong>, switches should be installed at a height of 1.2 to 1.4 meters from the floor.<\/p>\n<\/li>\n<li data-start=\"1761\" data-end=\"1826\">\n<p data-start=\"1763\" data-end=\"1826\">In <strong data-start=\"1766\" data-end=\"1776\">Zone 2<\/strong>, switches should be installed above 1.4 meters.<\/p>\n<\/li>\n<li data-start=\"1827\" data-end=\"1922\">\n<p data-start=\"1829\" data-end=\"1922\">In <strong data-start=\"1832\" data-end=\"1842\">Zone 1<\/strong>, outlets should be installed at a height of 0.4 to 1.2 meters from the floor.<\/p>\n<\/li>\n<li data-start=\"1923\" data-end=\"1987\">\n<p data-start=\"1925\" data-end=\"1987\">In <strong data-start=\"1928\" data-end=\"1938\">Zone 2<\/strong>, outlets should be installed above 1.2 meters.<\/p>\n<\/li>\n<li data-start=\"1988\" data-end=\"2095\">\n<p data-start=\"1990\" data-end=\"2095\">Special outlets for kitchen appliances, such as dishwashers, may have different placement requirements.<\/p>\n<\/li>\n<li data-start=\"2096\" data-end=\"2207\">\n<p data-start=\"2098\" data-end=\"2207\">Heat-generating appliances, like stoves, should be positioned at a safe distance from electrical equipment.<\/p>\n<\/li>\n<\/ul>\n<p><img decoding=\"async\" class=\"aligncenter wp-image-19352 size-full\" src=\"http:\/\/zemgroup.com\/en\/wp-content\/uploads\/2025\/10\/Kitchen-Zones1.webp\" alt=\"\" width=\"595\" height=\"286\" srcset=\"https:\/\/zemgroup.com\/en\/wp-content\/uploads\/2025\/10\/Kitchen-Zones1.webp 595w, https:\/\/zemgroup.com\/en\/wp-content\/uploads\/2025\/10\/Kitchen-Zones1-400x192.webp 400w, https:\/\/zemgroup.com\/en\/wp-content\/uploads\/2025\/10\/Kitchen-Zones1-430x207.webp 430w, https:\/\/zemgroup.com\/en\/wp-content\/uploads\/2025\/10\/Kitchen-Zones1-150x72.webp 150w\" sizes=\"(max-width: 595px) 100vw, 595px\" \/><\/p>\n<hr data-start=\"2209\" data-end=\"2212\" \/>\n<h3 data-start=\"2214\" data-end=\"2232\">Architecture<\/h3>\n<ul data-start=\"2234\" data-end=\"4239\">\n<li data-start=\"2234\" data-end=\"2365\">\n<p data-start=\"2236\" data-end=\"2365\">Floor areas and dimensions, including shelving, must be measured outside built-in cabinets, ledges, and door\/window thresholds.<\/p>\n<\/li>\n<li data-start=\"2366\" data-end=\"2525\">\n<p data-start=\"2368\" data-end=\"2525\">Access to living areas should not pass through the kitchen, but access to the kitchen should be available from the main space without obstructing activity.<\/p>\n<\/li>\n<li data-start=\"2526\" data-end=\"2668\">\n<p data-start=\"2528\" data-end=\"2668\">Minimum floor area, including under-shelf areas, should be <strong data-start=\"2587\" data-end=\"2597\">5.5 m\u00b2<\/strong>, and the minimum width between main walls should be <strong data-start=\"2650\" data-end=\"2665\">1.80 meters<\/strong>.<\/p>\n<\/li>\n<li data-start=\"2669\" data-end=\"2756\">\n<p data-start=\"2671\" data-end=\"2756\">At least <strong data-start=\"2680\" data-end=\"2691\">2.75 m\u00b2<\/strong> of free workspace outside shelving areas should be maintained.<\/p>\n<\/li>\n<li data-start=\"2757\" data-end=\"3019\">\n<p data-start=\"2759\" data-end=\"3019\">Independent kitchens must have natural light. For open or wall kitchens, artificial lighting and ventilation must be used if natural light and ventilation are not feasible and allowed by regulations. All kitchens must have mechanical exhaust systems (hoods).<\/p>\n<\/li>\n<li data-start=\"3020\" data-end=\"3162\">\n<p data-start=\"3022\" data-end=\"3162\">Floors of independent and open kitchens, and work areas in wall kitchens, should be covered with tiles or similar easy-to-clean materials.<\/p>\n<\/li>\n<li data-start=\"3163\" data-end=\"3300\">\n<p data-start=\"3165\" data-end=\"3300\">Walls around sinks and stoves in all kitchen types should be covered with tiles or similar materials up to <strong data-start=\"3272\" data-end=\"3287\">1.50 meters<\/strong> in height.<\/p>\n<\/li>\n<li data-start=\"3301\" data-end=\"3534\">\n<p data-start=\"3303\" data-end=\"3534\">Wall kitchens are not allowed in residential units larger than <strong data-start=\"3366\" data-end=\"3375\">75 m\u00b2<\/strong> if they open directly to the main living area. Open or wall kitchens in such units should not have a direct view of the primary cooking and workspace areas.<\/p>\n<\/li>\n<li data-start=\"3535\" data-end=\"3791\">\n<p data-start=\"3537\" data-end=\"3791\">Independent or open residential kitchens used only for cooking must have a minimum area of <strong data-start=\"3628\" data-end=\"3638\">5.5 m\u00b2<\/strong> and a minimum width of <strong data-start=\"3662\" data-end=\"3677\">1.80 meters<\/strong>; if used for cooking and dining, the minimum area should be <strong data-start=\"3738\" data-end=\"3748\">7.5 m\u00b2<\/strong> with a minimum width of <strong data-start=\"3773\" data-end=\"3788\">2.15 meters<\/strong>.<\/p>\n<\/li>\n<li data-start=\"3792\" data-end=\"3972\">\n<p data-start=\"3794\" data-end=\"3972\">Free workspace outside shelving areas must be at least <strong data-start=\"3849\" data-end=\"3860\">2.75 m\u00b2<\/strong>. For wall kitchens, a clear workspace at least <strong data-start=\"3908\" data-end=\"3923\">1.10 meters<\/strong> wide and <strong data-start=\"3933\" data-end=\"3945\">3 meters<\/strong> long must be maintained.<\/p>\n<\/li>\n<li data-start=\"3973\" data-end=\"4051\">\n<p data-start=\"3975\" data-end=\"4051\">Minimum ventilation openings should be <strong data-start=\"4014\" data-end=\"4048\">1\/16 of the kitchen floor area<\/strong>.<\/p>\n<\/li>\n<li data-start=\"4052\" data-end=\"4239\">\n<p data-start=\"4054\" data-end=\"4239\">If kitchen and living areas receive light and air from separate residential units or an internal courtyard, the distance between opposing windows should not be less than <strong data-start=\"4224\" data-end=\"4236\">4 meters<\/strong>.<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"4241\" data-end=\"4244\" \/>\n<h3 data-start=\"4246\" data-end=\"4269\">Civil Engineering<\/h3>\n<p data-start=\"4271\" data-end=\"4408\">From a civil design perspective, kitchens are categorized into five layout types: <strong data-start=\"4353\" data-end=\"4405\">linear, L-shaped, U-shaped, island, and corridor<\/strong>.<\/p>\n<ul data-start=\"4410\" data-end=\"5648\">\n<li data-start=\"4410\" data-end=\"4532\">\n<p data-start=\"4412\" data-end=\"4532\">The sink should be placed as far as possible from the stove to prevent dirt or grease from contaminating clean dishes.<\/p>\n<\/li>\n<li data-start=\"4533\" data-end=\"4667\">\n<p data-start=\"4535\" data-end=\"4667\">The stove should not be placed near or under windows, which could extinguish flames or cause fire hazards if curtains are present.<\/p>\n<\/li>\n<li data-start=\"4668\" data-end=\"4866\">\n<p data-start=\"4670\" data-end=\"4866\">Stoves should not be installed too close to refrigerators, as heat can negatively affect refrigerator performance. A minimum clearance of <strong data-start=\"4808\" data-end=\"4817\">40 cm<\/strong> on both sides of the stove must be maintained.<\/p>\n<\/li>\n<li data-start=\"4867\" data-end=\"5056\">\n<p data-start=\"4869\" data-end=\"5056\">The <strong data-start=\"4873\" data-end=\"4898\">kitchen work triangle<\/strong> must be followed, consisting of the sink, stove, and refrigerator, ideally forming an equilateral triangle with a total walking distance of 10 to 25 steps.<\/p>\n<\/li>\n<li data-start=\"5057\" data-end=\"5250\">\n<p data-start=\"5059\" data-end=\"5250\">Linear kitchens cannot always accommodate the work triangle properly; short walls bring appliances too close, while long walls spread them too far apart, increasing fatigue during movement.<\/p>\n<\/li>\n<li data-start=\"5251\" data-end=\"5397\">\n<p data-start=\"5253\" data-end=\"5397\">In one-sided linear kitchens, a minimum of <strong data-start=\"5296\" data-end=\"5305\">90 cm<\/strong> of free space should be maintained in front of cabinets and appliances for safe movement.<\/p>\n<\/li>\n<li data-start=\"5398\" data-end=\"5468\">\n<p data-start=\"5400\" data-end=\"5468\">For corridor kitchens, the minimum aisle width must be <strong data-start=\"5455\" data-end=\"5465\">107 cm<\/strong>.<\/p>\n<\/li>\n<li data-start=\"5469\" data-end=\"5543\">\n<p data-start=\"5471\" data-end=\"5543\">Minimum entrance door width: <strong data-start=\"5500\" data-end=\"5509\">88 cm<\/strong>; for open kitchens: <strong data-start=\"5530\" data-end=\"5540\">102 cm<\/strong>.<\/p>\n<\/li>\n<li data-start=\"5544\" data-end=\"5648\">\n<p data-start=\"5546\" data-end=\"5648\">Minimum floor area under shelving: <strong data-start=\"5581\" data-end=\"5591\">5.5 m\u00b2<\/strong>, and minimum width between main walls: <strong data-start=\"5631\" data-end=\"5645\">1.8 meters<\/strong>.<\/p>\n<\/li>\n<\/ul>\n<hr data-start=\"5650\" data-end=\"5653\" \/>\n<h3 data-start=\"5655\" data-end=\"5664\">Gas<\/h3>\n<ul data-start=\"5666\" data-end=\"6015\">\n<li data-start=\"5666\" data-end=\"5904\">\n<p data-start=\"5668\" data-end=\"5904\">Gas piping must provide a volume of <strong data-start=\"5704\" data-end=\"5713\">40 m\u00b3<\/strong> with standard sealing, assuming 3 meters in height and 14 m\u00b2 area. Otherwise, combustion air must be supplied through a permanent vent to the outside with a minimum opening of <strong data-start=\"5890\" data-end=\"5901\">645 cm\u00b2<\/strong>.<\/p>\n<\/li>\n<li data-start=\"5905\" data-end=\"6015\">\n<p data-start=\"5907\" data-end=\"6015\">Non-compliance with any of these engineering regulations may result in refusal of final building approval.<\/p>\n<\/li>\n<\/ul>\t\t\t\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t\t\t<\/div>\n\t\t","protected":false},"excerpt":{"rendered":"<p>The kitchen is one of the most important spaces in any residential or commercial building, as its functionality and safety<\/p>\n","protected":false},"author":2,"featured_media":19353,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[141],"tags":[],"class_list":["post-19351","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-articles"],"_links":{"self":[{"href":"https:\/\/zemgroup.com\/en\/wp-json\/wp\/v2\/posts\/19351","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/zemgroup.com\/en\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/zemgroup.com\/en\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/zemgroup.com\/en\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/zemgroup.com\/en\/wp-json\/wp\/v2\/comments?post=19351"}],"version-history":[{"count":4,"href":"https:\/\/zemgroup.com\/en\/wp-json\/wp\/v2\/posts\/19351\/revisions"}],"predecessor-version":[{"id":19358,"href":"https:\/\/zemgroup.com\/en\/wp-json\/wp\/v2\/posts\/19351\/revisions\/19358"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/zemgroup.com\/en\/wp-json\/wp\/v2\/media\/19353"}],"wp:attachment":[{"href":"https:\/\/zemgroup.com\/en\/wp-json\/wp\/v2\/media?parent=19351"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/zemgroup.com\/en\/wp-json\/wp\/v2\/categories?post=19351"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/zemgroup.com\/en\/wp-json\/wp\/v2\/tags?post=19351"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}